F-01 Certified Fire Guards
| Fire Guards | Typical Fire Guards | F-01 Certified |
|---|---|---|
| FDNY Compliance | ❌ Uncertified | ✅ Legal requirement |
| Impairment Knowledge | Basic | ✅ Trained per NFPA 25/FC 401 |
| Response Time | 4-24 hours | ✅ <2 hours (avg.) |
| Violation Risk | Medium | ✅ 0% (since 2020) |
Need Hot Work Fire Watch?


24/7 Emergency Hot Work Fire Watch
A single violation posted to the job trailer can idle two hundred trades and push your completion date into winter premium months. Our hot work fire watch guard arrives before the striker arc is grounded, verifies the permit matches the actual ignition point, and positions the required extinguisher within the thirty-five-foot radius mandated by OSHA 1926.352.
During cutting he maintains a clear line of sight to the weld, logs each start and stop time with GPS coordinates, and radios for an extension if wind speed exceeds the 25mph limit. Inspectors arrive unannounced; the guard presents bound logs, guard license, and hot-work permit in under two minutes, demonstrating full compliance and preventing the stop-work order. When parallel trades store solvent rags near the operation, he halts work, removes the combustible load, and photographs the corrected area for your records.

24 Hour Fire Watch Security Services
Get Lawsuit-Proof Fire Watch GuardsSmoldering insulation inside a wall cavity can burst into flame four hours after the welder clocks out, exposing the project to catastrophic loss and seven-figure subrogation. Our guard ends each hot work session with a calibrated infrared thermometer, sweeping ceiling voids, beam pockets, and deck insulation for temperature spikes above ambient. Any reading above one hundred forty degrees Fahrenheit triggers immediate exposure: the guard removes the suspect material, floods the area with water, and logs thermal images time-stamped to the minute.
A second scan is performed thirty minutes later to confirm the site has returned to baseline. These digital records have already saved three general contractors from insurance denial by proving the fire originated six hours after our shift concluded.

24 Hour Fire Guard Services
Emergency DeploymentCritical path schedules do not recognize weekends. When steel erection must continue through Saturday night to meet a crane demobilization deadline, our weekend hot work fire watch teams are already on site, fully briefed, and permit-ready. We maintain the same F-01 certification, GPS logging, and extinguisher standards that govern weekday shifts, ensuring zero drop-off in compliance or documentation quality.
The guard coordinates with your night superintendent, monitors wind speed with continuous digital anemometer readings, and files hourly reports that integrate seamlessly with Monday morning inspector visits. Holiday premiums are locked at pre-agreed rates, eliminating surprise overtime charges that erode trade budgets. Over the past twelve months we have supplied 400 weekend shifts without a single violation.

Fire Watch Security Services
Request a Free Quote Now99%
Available 24/7
Contact us anytime
100%
Fire Marshall Compliant
100% certified guards
99%
Fully Equipped
Hire the best
98%
Skilled & Experienced
12+ years experience
24 Hour Fire Watch Guard Services
Call or message us now to get startedAny welding, cutting, grinding, or open flame operation requires a certified fire watch guard when combustible materials are within thirty-five feet. The mandate also applies when standpipe, sprinkler, or alarm systems are impaired, or when wind speed exceeds twenty-five miles per hour. Our team arrives with the correct class of extinguisher and digital logs to keep the operation compliant from the first spark.
The guard conducts a final inspection and stays on site for thirty minutes, then returns for a second check thirty minutes later. If concealed spaces or insulation are present, the interval is extended to one hour. All temperature readings are logged with GPS time stamps to provide verifiable proof of proper close-out for inspectors and insurers.
Guards must hold current 30-hour OSHA construction training, NFPA 241 site fire watch certification, and first aid/CPR. In New York City, an F-01 Certificate of Fitness is required for operations above 75 feet or during standpipe impairment. Our personnel carry these credentials and complete quarterly hot work safety refreshers to maintain compliance with local fire codes.
A single guard may oversee several torches only if they are within 35 feet of one another and remain in his direct line of sight. Separate floors, opposite ends of a wing, or inside and outside work require individual guards. We map the site in advance to ensure proper coverage ratios and eliminate blind spots that could result in a violation.
Liability depends on documentation. Our guards provide bound logs that include final temperature readings, thermal scan images, and supervisor sign-off confirming the area returned to ambient conditions. These records have protected clients from seven-figure subrogation claims by proving the fire started hours after our watch concluded. Without proper close-out evidence, contractors can be held responsible for latent fires that emerge later.